1785 slot on drive array not configured no drives detected

I had this question after viewing How to diagnose/replace RAID drive HP Proliant Smart Array. Just purchased an older HP DL380 G6 server, purchased new drives but won't recognize any of the drives... HP DL380 G6 Smart Array P410i No Drives Detected Repair Hp Blade Post Error 1785-drive Array Not Configured ... Figure 05: During POST, Smart -> Embedded Storage -> Dynamic Smart Array B140i and press Enter. Figure 01 Shows "1785-Slot 0b Drive Array Not Configured No 1785 Slot 0 Drive Array Not Configured No Drives Detected Look in the System Management Homepage and Array Configuration Utility and checked my arrays.

thr3ads.net - CentOS - [CentOS] Problem detecting HP Tape… Slot 3 HP Smart Array 6400 Controller (192MB, v.2.26) 1 Logic Drive Detected 1794-Slot 3 Drive Arraye - Array Accelerator Battery Charge low Array Accelerator Posted-Write Cache is temporarilty DisabledSCSI Port 2: SCSI ID 1 1785-Slot 3 Drive Arraye Not Configured No Drives Detected ... Fix Post Error 1785-slot X Drive Array Not Configured -… The RAID controller is refusing to recognize inserted drives as an array…. IBM MegaRAID BIOS Config Utility RAID-10 Configuration …The standard RAID levels are a basic set of RAID configurations that employ the techniques of striping, mirroring, or parity to create large reliable data... HP Proliant ML350 Server has lost RAID configuration on…

1785-Slot X Drive Array Not Configured (HP Proliant ML10 ...

Захотели поставить еще один HDD в сервер Proliant DL 380. Запросили цену, SATA, 2 TB, 2.5'' от HP. Ахнули, и решили попробовать другой вариант. Купить у HP салазки, а диск отдельно. Вышло раза в... Proliant 1500 и RedHat 6.2 Initialization Aborted 172-1 Configuration Nonvolatile Memory Invalid Slot 6 Drive Array Initializing 1785-Slot 6 Drive Array not Configured 162-SystemOriginal Smart Порядок контроллера должен быть first OS Selection for Array должно быть Unix/Xenix F10 - Готово "Шаг 5: Сохранить и выйти"... 1785 drive array not configured no drives detected HP…

Repair Iml Post Error 1785-drive Array Not Configured ...

getting drive array problem Trying to set up an old DL 380. At boot I get an error; Slot 0 drive array not - HP Compaq ProLiant DL380 G4 question.At boot I get an error; Slot 0 drive array not configured - no drives detected. Don't know what to do from here. Posted by jimshea537 on Dec 08...

Folks, I have attached a 6400 scsi controler 6400 on my HP DL 380 G5 running Oracle Unbreakable Linux 4 to make a backup to a Dell Power Vault 100 T tape drive. 1. On the first screen BIOS detection it shows that theres is a 6400 scsi controler 2. Shows that has detected a TAPE or CD-ROM device because i already conected the Tape Drive to it; 3. The first time i booted the kudzo showed up and

do not require the full feature set of HPE Smart Array Controllers. Available HPE Smart HBA Controllers HPE offers four different SAS HBA Controllers for ProLiant Gen9 Servers (Table 1). The H240ar is a daughterboard controller designed for HPE ProLiant Gen9 300 series ML and DL Servers , providing direct attached storage without using a PCIe slot. Hp proliant ml350 g4p +windows server 2003 - Windows serveur 185-Slot 3 Drive Array ot Configured no Drives Detected ... 0 Logical Drives 1785-Slot 3 Drive Array not Configured no Drives Detected. Reply. Leave a Replay.

14 июл 11, 12:04 [10972434] Ответить | Цитировать Сообщить модератору. Re: Drive Array Controller Failure - пипец [new]. Khod Member. Откуда: Ukraine, Kirovograd Сообщений: 6958. Шил, наверно, при вставленных дисках? 14 июл 11, 12:26 [10972643]...

HPE Support document - HPE Support Center Notice: "1785-Slot 0 Drive Array Not Configured - No Drives Detected" POST Message Appears on HP ProLiant ML350 G5 Server if No Hard Drives Are Attached to the Integrated HP Smart Array E200i Controller No disk drives detected on DL380 G6 - Hewlett Packard ... No disk drives detected on DL380 G6 ... "Slot 0 HP Smart Array P410i Controller 0 Logical Drives 1785-Slot 0 Drive Array Not Configured No Drives Detected" It looks like a hardware component failed. Is this an array controller or system board problem? 0 Kudos Reply. All forum topics ... How can I force HP Smart Array RAID controller to re ...

Drive Array Controller Failure - пипец / Hardware / Sql.ru |… 14 июл 11, 12:04 [10972434] Ответить | Цитировать Сообщить модератору. Re: Drive Array Controller Failure - пипец [new]. Khod Member. Откуда: Ukraine, Kirovograd Сообщений: 6958. Шил, наверно, при вставленных дисках? 14 июл 11, 12:26 [10972643]... Ошибка "BOOT FAIL" при загрузке сервера HP ProLiant…